MODEL No's
Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give
you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. CONTENTS
Section 2.
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.
Section 2.1 Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.
Section 2.2. Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.
Section 3.
Safety/Operational Instructions. . . . . . . . . . . . . . . . . . .2.
Section 4.
Maintenance/Examination/Inspection. . . . . . . . . . . . . .2.
Section 5.
Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.
Section 6.
Owner's & Operator's Responsibilities . . . . . . . . . . . . .2.
Section 7.
Declaration of Conformity. . . . . . . . . . . . . . . . . . . . . . .3.
2. GENERAL
2.1
Identification
Supplier:
Sealey Power Products,
Kempson Way,
Suffolk Business Park,
Bury St Edmunds,
Suffolk, IP32 7AR.
Model No:
BC1000.V2, BC2000.V2, BC3000.V2, BC5000.V2
2.2
Technical Data
Rated Capacity
BC1000.V2 - Safe Working Load (SWL) 1t (tested to 25% overload).
BC1000.V2 - Working Load Limit (WLL) 1t (tested to 25% overload).
BC2000.V2 - Safe Working Load (SWL) 2t (tested to 25% overload).
BC2000.V2 - Working Load Limit (WLL) 2t (tested to 25% overload).
BC3000.V2 - Safe Working Load (SWL) 3t (tested to 33% overload).
BC3000.V2 - Working Load Limit (WLL) 3t (tested to 33% overload).
BC5000.V2 - Safe Working Load (SWL) 5t (tested to 26% overload).
BC5000.V2 - Working Load Limit (WLL) 5t (tested to 26% overload).
a)
Design Capability: BC1000.V2 Test Load 25% overload.
BC2000.V2 Test Load 25% overload.
BC3000.V2 Test Load 33% overload.
BC5000.V2 Test Load 26% overload.
b)
For a description of in-service and out-of-service conditions see
Section 3 Safety, Section 4 Maintenance and Section 6.
BC1000.V2
INSTRUCTIONS FOR:
BEAM CLAMP
BC2000.V2
Page No.
Note: Letters refer to dimensions shown in fig.1.
Model No: BC1000.V2
Capacity:
1000kg
A
260mm
B
180-360mm
C
D
E
215mm
F
102-155mm
G
H
BC1000.V2, BC2000.V2, BC3000.V2, BC5000.V2 Issue: 1 - 24/04/09
PAGE 1
BC3000.V2
BC2000.V2
BC3000.V2
2000kg
260mm
180-360mm
235-490mm
64mm
74mm
5mm
6mm
235mm
102-155mm
140-225mm
25mm
25mm
22mm
22mm
BC5000.V2
BC5000.V2
3000kg
5000kg
390mm
400mm
235-500mm
103mm
110mm
8mm
10mm
270mm
290mm
140-225mm
45mm
45mm
24mm
28mm