Content Index 1. General Safety Instructions ..................3 1.1 SAFETY: General Safety ..................3 1.2 SAFETY: General Power Safety ................5 2. Exploded view diagram with list of items ..............6 3. Wiring connectivity diagram ..................7 4. Disassembly and Assembly Procedures ..............8 4.1 Disassembly SOP ....................
IMPORTANT NOTICE FOR USE IN HEALTHCARE ENVIRONMENTS: Dell products are not medical devices and are not listed under UL or IEC 60601 (or equivalent). As a result, they must not be used within 6 feet of a patient or in a manner that directly or indirectly contacts a patient 1.1 SAFETY: General Safety...
Page 4
When operating your equipment: Do not use your equipment in a wet environment, for example, near a bath tub, sink, or swimming pool or in a wet basement. Do not use AC powered equipment during an electrical storm. Battery powered devices may be used if all cables have been disconnected.
socket. If your equipment uses an AC adapter: Use only the Dell provided AC adapter approved for use with this device. Use of another AC adapter may cause a fire or explosion. NOTE: Refer to your system rating label for information on the proper adapter model ...
4. Disassembly and Assembly Procedures 4.1 Disassembly SOP Preparation before disassemble 1. Clean the room for disassemble 2. Identify the area for monitor 3. Check the position that the monitors be placed and the quantity of the monitor; prepare the area for material flow;...
Page 9
1. Tear off the AL foil 2. Pull out Control board cable, wire and USB board cable 3. Take off main shielding from middle frame 4. Tear off adhesive tape from LVDS cable 5. Pull out LVDS cable and take off main shielding from panel 1.
4.2 Assembly SOP Preparation before assemble 1. Clean the room for work 2. Identify the area for material 3. Prepare the implement, equipment, material as bellow: 1) Working table 2) Philips-head screwdriver 3) Glove 4) Cleaning cloth 5) ESD protection Item Picture Operation...
Page 11
1. Insert LVDS cable into interface on panel and paste acetate tape 2. Locate Main Shielding on middle frame 1. Insert wire into SPS board 2. Arrange the control board cable and insert control board cable into I/F board 3. Fix control board cable on the panel and main shielding, and cover a piece of AL foil on the hole...
Page 12
To attach the monitor stand: 1. Follow the instructions on the flaps of carton to remove the stand from the top cushion that secures it 2. Insert the stand base blocks fully into the stand slot 3. Lift the screw handle and turn the screw clockwise 4.