5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 3 Note to the installer Note to the customer Parts supplied - double & single models Tools needed Installation preparation - double & signle models Electrical information - double & single models Service specifications - double models The cavity - double models Plumbing options - double models Service specifications - single models...
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 4 Note to the installer 1. Read these instructions completely and carefully. 2. Installation of this requires basic mechanical and electrical skills. 3. Be sure to leave these Instructions with the Customer. 4. At the completion of the installation, the Installer must perform Final Check List as per Section 11 of these Installation Instructions.
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 6 Installation preparation - double & signle models ELECTRICAL PREPARATION A) The switched power outlet for the appliance should be installed in a cabinet or on a wall adjacent to the under bench space in which the appliance is to be installed. Note: The power outlet must be accessible after installation.
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 7 Electrical information - double & single models POWER SUPPLY CORD A) Care should be taken when the appliance is installed or removed, to reduce the likelihood of damage to the power supply cord. B) If the power supply cord is damaged, it must be replaced by the Manufacturer, Service Agent or a similarly qualified person, in order to avoid a hazard.
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 8 Service specifications - double models WATER CONNECTION Recommended COLD (Maximum 60°C). 3/4 “ BSP (GB20) to suit flat washer. WATER SOFTENER MODELS Refer to your User Guide on how to set up your water softener. WATER PRESSURE Maximum Minimum...
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 9 The cavity - double models Screw 14mm From 109.5mm front of cabinetry 10mm benchtop moisture protection Moisture 90° tape Protection 10mm Tape Min thickness of cavity sides is 16mm Ø50mm services hole immediately adjacent to corner, can be either side 97mm...
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 10 Plumbing options - double models OPTION 1 and Standpipe Ø38mm with Air Gap. WASTE WATER SUPPLY POWER VALVE OUTLET 200mm WASTE MINIMUM BENDS RADIUS FROM VALVE OPTION 2 with Waste Disposal. Standpipe Ø38mm with Air Gap. WASTE PLEASE NOTE: It is NOT recommended to connect the...
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 11 Service specifications - single models WATER CONNECTION Recommended COLD (Maximum 60°C). 3/4 “ BSP (GB20) to suit flat washer. WATER SOFTENER MODELS Refer to your User Guide on vhow to set up your water softener. WATER PRESSURE Maximum Minimum...
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 12 The cavity - single models 10mm benchtop moisture Moisture protection 90° Protection Tape tape 10mm Ø50mm services hole Minimum immediately thickness of adjacent to corner, cavity sides can be either side 97mm is 16mm 580mm throughout cavity 67mm 600mm...
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 13 Plumbing options - single models OPTION 1 and Standpipe Ø38mm with Air Gap. POWER OUTLET WASTE WATER SUPPLY VALVE 200mm MINIMUM WASTE BENDS RADIUS FROM VALVE OPTION 2 with Waste Disposal. Standpipe POWER Ø38mm with Air Gap. OUTLET WASTE PLEASE NOTE: It is NOT recommended to...
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 14 Installation instructions PLEASE NOTE: Your model of may differ from the model shown in the installation diagrams. Installation is similar for all models either Single or Double. Information referring to Single models only is in italic.
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 15 Step 2: removing the tub Important! (SINGLE MODELS ONLY) The product may move. Mark chassis position on cavity. 4 SINGLE MODELS ONLY. Gently open the drawer and mark the chassis position on the cavity, before removing the tub. 5 Open the drawer (Bottom drawer in DOUBLE MODELS).
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 16 Step 3: adjusting the feet (double models only) 9 - DOUBLE MODELS ONLY Adjust the height of the product to suit the cabinetry, by turning the feet from inside the product using a wrench or M5 socket. TIP - Gently take the load off each foot using the slide and then turn by hand.
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 17 Step 4: securing the product 10 SINGLE MODELS ONLY Check the position of the chassis is still where marked on the cavity, before securing the product. 11 There are four 16mm round holes, two on the left and two on the right hand side in the sound insulation.
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 18 Step 6: connecting the drain hoses with Hose Joiner (see Plumbing Options). WIRE CLIP WIRE Remember to slip the wire clip(s) on the drain hose(s) first. CLIP SINGLE DRAIN DRAIN HOSE 15a Slip a wire clip over each drain hose, then push the hoses into HOSE JOINER WASTE DOUBLE...
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 19 Step 7: connecting the inlet hose and power supply WARNING! WENT DO NOT plug the product in at this stage. WASTE Important! DO NOT cut the inlet hose. VALVE WATER POWER SUPPLY OUTLET 17 Connect the Inlet Hose to the water supply. Ensure the sealing 200mm MINIMUM washer is in place.
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 20 Step 9: trimming the toe kick (double models only) Important! Before cutting ensure the Toe Kick is positioned on a wooden chopping board to avoid damage to surrounding area. 20 On the chosen groove cut down the vertical ribs at the centre and the ends using a knife.
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 21 Step 11: Final checklist (double and single models) • Ensure product is level, securely fastened to the cabinetry and opens and closes freely. The must be free to close with no resistance from the cabinetry. •...
Page 22
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 22...
Page 23
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 23...
Page 24
5019_102_00273_INSTAL_GB 30-05-2007 13:25 Pagina 24 Printed in Italy 05/07 5019 102 00273...