The signal word "NOTICE" indicates useful or important information about the product. The signal word "NOTICE" is not a signal word indicating a danger to personnel. The signal word "NOTICE" can also refer to material damage. 4 CI/EDP300-EN Rev. C | PositionMaster EDP300...
IP rating is met. EAC TR-CU-012 Ex ia IIC T4/T6 Ga X Ex ia IIIC T100°C/T55°C Da IP65 EX nA IIC T4/T6 Gc X Ex tb IIIC T100°C/T55°C Db IP65 PositionMaster EDP300 | CI/EDP300-EN Rev. C 5...
Ventilate and evacuate the EDP300 fully several times. Terminals +83 / -84 Temperature class T1 – T4 Temperature class T6 = 30 V = 28 V = 500 mW = 400 mW = 4.2 nF = negligibly small 6 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Terminals Limit 1: +51 / -52 Limit 2: +41 / -42 Temperature class T1 – T4 Temperature class T6 In accordance with type examination certificate PTB 00 ATEX 2049X 1) No IECEx approval PositionMaster EDP300 | CI/EDP300-EN Rev. C 7...
Temperature class Ambient temperature T T1 ... T4 -40 °C ... 85 °C -40 °C ... 40 °C Temperature class Ambient temperature T -40 °C ... 85 °C -40 °C ... 40 °C PositionMaster EDP300 | CI/EDP300-EN Rev. C 9...
Page 10
Limit 1: +51 / -52 Limit 2: +41 / -42 Temperature class T1 – T4 Temperature class T6 -25 … 85 °C -25°C … 40°C 1) No IECEx approval Change from two to one column 10 CI/EDP300-EN Rev. C | PositionMaster EDP300...
All claims for damages must be submitted to the shipper without delay and before installation. must observe the following regulations for shipping purposes: All devices delivered to ABB must be free from any hazardous materials (acids, alkalis, solvents, etc.). Please contact Customer Center Service acc. to page 2 for nearest service location.
If the device is being operated on a cylinder, for reasons associated with linearity you should run the Auto Adjust function for rotary actuators (see chapter "Start Auto Adjust function" on page 31). 12 CI/EDP300-EN Rev. C | PositionMaster EDP300...
The usable span is 90°, which must be entirely within the measuring range, but does not necessarily need to run symmetrically to the longitudinal axis. NOTICE During installation make sure that the actuator travel or rotation angle for position feedback is implemented correctly. PositionMaster EDP300 | CI/EDP300-EN Rev. C 13...
Page 14
Tighten the screws as evenly as possible to ensure subsequent linearity. Align the mount bracket in the oblong hole to ensure that the operating range is symmetrical (lever moves between the arrow marks 4 ). 14 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Page 15
After mounting, check whether the positioner is operating within the sensor range. M11032 Fig. 12: Actuator bolt on valve (rear view) 1 Potentiometer lever 2 Actuator bolts c Valve spindle d Vent lamp e Positioner PositionMaster EDP300 | CI/EDP300-EN Rev. C 15...
Required tools: — Wrench, size 8 / 10 — Allen key, size 3 Fig. 14: Integral mounting on control valves using adapter plate 1 O-Ring 2 Adapter plate 3 Adapter 16 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Page 17
Fig. 18: Screwing the positioner onto the actuator NOTICE After mounting, check whether the operating range for the actuator matches the measuring range for the positioner, see chapter "General information" on page 13. PositionMaster EDP300 | CI/EDP300-EN Rev. C 17...
(Option module) +21 / -22 Universal input UAI 1 / 2 / 3 EDP300 remote sensor (Only for options EDP300 Remote Sensor or EDP300 for remote position sensor) Change from two to one column 18 CI/EDP300-EN Rev. C | PositionMaster EDP300...
(Control circuit in accordance with DIN 19234/NAMUR) Switching state logical “0”: Current > 0,35 mA … < 1,2 mA “1”: Current > 2,1 mA Direction of action standard logical "0" or logical "1" (configurable) PositionMaster EDP300 | CI/EDP300-EN Rev. C 19...
Page 20
400 Ω at 20 mA Terminals 41 / 42 / 43, 51 / 52 / 53 Supply voltage maximum 24 V AC/DC Load rating Maximum 2 A Change from two to one column 20 CI/EDP300-EN Rev. C | PositionMaster EDP300...
0.25 ... 0.5 mm (AWG 23 ... AWG 22) sleeve no plastic sleeve Flexible with wire end 0.25 ... 0.5 mm (AWG 23 ... AWG 22) sleeve with plastic sleeve Change from two to one column PositionMaster EDP300 | CI/EDP300-EN Rev. C 21...
(0.44 lbf-in) and then tighten by applying 200 Ncm (1.77 lbf-in). — The pneumatic outputs must be connected to the actuator using pneumatic lines with a minimum diameter of 6 mm. Change from two to one column 22 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Auto Adjust function for rotary actuators — The pneumatic outputs must be connected to the actuator using pneumatic lines with a minimum diameter of 6 mm. PositionMaster EDP300 | CI/EDP300-EN Rev. C 23...
4. Attach the new housing cover (with round viewing window) and screw it on to the housing. Tighten the screws so that they are hand-tight. 24 CI/EDP300-EN Rev. C | PositionMaster EDP300...
2 when the feedback shaft is rotated counter-clockwise (as viewed from the front). 3. Attach the housing cover and screw it onto the housing. 4. Tighten the screws so that they are hand-tight. PositionMaster EDP300 | CI/EDP300-EN Rev. C 25...
It enables the increased pressure to be transferred back to the air inlet line. The opening pressure of the check valve should be < 250 mbar (< 3.6 psi). 26 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Operating Mode menu. Operating mode Auto Adjust Adaptive Control Manual SP Manual Sensor Configuration Back 2. Use to select the "Manual Sensor" operating mode. 3. Use to move to the relevant end positions. 28 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Exit menu Back Go back one submenu Cancel Cancel parameter entry Select the next position for entering numerical Next and alphanumeric values Meaning Select Select submenu / parameter Edit parameter Edit Save parameter entered PositionMaster EDP300 | CI/EDP300-EN Rev. C 29...
Prior to external configuration, always move the actuator to the safety position and activate manual adjustment. NOTICE For detailed information on the parameterization of the device, consult the associated operating instructions and configuration and parameterization instructions. 30 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Dead band time limit Setting range 0 ... 200 seconds successfully, "Auto Adjuste Complete" is displayed. The (monitoring parameter for control until the device then switches to the process display automatically. deviation reaches the dead band) PositionMaster EDP300 | CI/EDP300-EN Rev. C 31...
< 1 % to 10 g and 80 Hz 1) Freely configurable with 20 reference points Trademarks ® HART is a registered trademark of FieldComm Group, Austin, Texas, Change from two to one column 32 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Which substances have come into contact with the device? We hereby state that the devices / components shipped have been cleaned and are free from any dangerous or poisonous substances. Town/city, date Signature and company stamp PositionMaster EDP300 | CI/EDP300-EN Rev. C 33...
12.2 Control Drawing 901305 34 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Page 35
PositionMaster EDP300 | CI/EDP300-EN Rev. C 35...
Page 36
36 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Page 37
PositionMaster EDP300 | CI/EDP300-EN Rev. C 37...
Page 38
38 CI/EDP300-EN Rev. C | PositionMaster EDP300...
Page 39
PositionMaster EDP300 | CI/EDP300-EN Rev. C 39...
Page 40
Howard Road, St. Neots notice. Cambridgeshire, PE19 8EU With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or Tel: +44 (0)870 600 6122 possible lack of information in this document.