This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective March 2018
Specifications are subject to change without notice.
©
2004 MITSUBISHI ELECTRIC CORPORATION
Safety Precautions
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury or
physical damage.
Depending on the circumstances, procedures indicated by
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
FX
/FX
/FX
/FX
/
Describes specifications for
3S
3G
3GC
3U
JY997D16701
FX
Series
analog control and programming
3UC
MODEL CODE:
User's Manual
method for FX
/FX
3S
3G
09R619
- Analog Control Edition
FX
3U
/FX
3UC
Series PLC.
FX
/FX
/FX
/FX
/
3S
3G
3GC
3U
FX
3UC
Series
JY997D16601
Describes PLC programming for
Programming Manual
MODEL CODE:
basic/applied instructions and
- Basic & Applied
09R517
devices.
Instruction Edition
FX
Series
JY997D28701
Explains the FX
Series PLC
3UC
3UC
User's Manual
MODEL CODE:
specifications for I/O, wiring,
- Hardware Edition
09R519
installation, and maintenance.
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
Certification of UL, cUL standards
The following product has UL and cUL certification.
UL, cUL File Number:E95239
Models:
MELSEC FX
3UC
series manufactured
-
FX
4AD
3UC
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more details please contact the
local Mitsubishi Electric sales site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the
identified standards below) and design analysis (through the creation of a
technical construction file) to the European Directive for Electromagnetic
Compatibility (2014/30/EU) when used as directed by the appropriate
documentation.
Side
B
Attention
This product is designed for use in industrial applications.
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
series manufactured
3UC
from October 1st, 2007
FX
3UC
-4AD
Standard
EN61131-2:2007
Compliance with all relevant aspects of the
Programmable controllers
standard.
- Equipment requirements and
EMI
tests
• Radiated Emission
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
Caution for EC Directive
The FX
-4AD have been found to be compliant to the European standards in
3UC
the aforesaid manual and directive. However, for the very best performance
from what are in fact delicate measuring and controlled output device Mitsubishi
Electric would like to make the following points;
As analog devices are sensitive by nature, their use should be considered care-
fully. For users of proprietary cables (integral with sensors or actuators), these
users should follow those manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used. If NO other
EMC protection is provided, then users may experience temporary loss or
accuracy between ±10% in very heavy industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC precautions are fol-
lowed for the users complete control system, users should expect accuracy as
specified in this manual.
• Sensitive analog cable should not be laid in the same trunking or cable
conduit as high voltage cabling. Where possible users should run analog
cables separately.
• Good cable shielding should be used. Ground the shield of the twisted
shielded cable at one point on the PLC side.
• When reading analog values, EMC accuracy can be improved out by
averaging the readings. This can be achieved either through functions on the
special function block for analog input or through a users program in the
FX
3UC
Series PLC main unit.
• Please use FX
-4AD while installed in a shielded enclosure. For the
3UC
details, refer to the following manual.
→ Refer to the FX
Series User's Manual - Hardware Edition
3UC
may also
Note for compliance with EN61131-2:2007
General note on the use of the power supply cable.
The FX
-4AD unit requires that the cable used for power supply is 30m or less.
3UC
1. Outline
The FX
3UC
-4AD special function block (hereinafter called 4AD) for analog input
converts four analog input values (voltage, current) to digital values and transfers those
digital values to the PLC main unit. For the purpose of this manual the FX
from here be referred to as the 4AD.
/FX
/
3GC
2. Incorporated Items
Verify that the following product and items are included in the package:
Product
FX
-4AD special function block for analog input
3UC
• Special unit/block No. label
• FX
Accessories
-10BPCB1 (Power crossover cable)
2NC
• Installation manual (This manual)
3.
External Dimensions, Part Names, and Terminal Layout
20.2
15
(0.8")
[2]
(0.6")
FX
3UC
-4AD
[1]
Remark
PW
24V
A/D
[3]
[7]
[8]
Unit: mm (inches)
Mass (Weight) : Approx.130g (0.29lbs)
[1] Status indicator LED
-
PW (Green): Lit while 5 V power is normally supplied from PLC.
-
24V (Red): Lit while 24V power is normally supplied from power supply.
-
A/D (Red): Flashes during A/D conversion.
[2] Terminal block (European type)
Wiring of the voltage and current input
[3] Connector (PLC side)
Used to fix extension block on right side.
[4] DIN rail mounting hook
[5] Slide lock
Used to connect the FX
main unit extension block.
3UC
[6] Connector (Extension side)
Used to connect extension block on right side of this special block.
Remove this cover for connecting.
[7] Power connector (24V DC)
The connector for supplying 24V power supply to 4AD.
[8] Power crossover connector
Used to supply power supply to the extension block.
-4AD will
4. Installation
3UC
The 4AD can be installed on a DIN46277 rail (35 mm (1.38") wide).
INSTALLATION
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
• Use screwdrivers carefully when performing installation work, thus avoiding accident
or product damage.
• Use the product within the generic environment specifications described in PLC main
unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl
, H
S, SO
2
2
expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
• When drilling screw holes or wiring, make sure that cutting and wiring debris do
not enter the ventilation slits of the PLC.
Failure to do so may cause fire, equipment failures or malfunctions.
• Connect FX
-4AD securely to their designated connectors.
3UC
Loose connections may cause malfunctions.
*1
Up to 8 units
can be connected to the FX
*1 Up to 7 units can be connected to the FX
4.1 Connection to the PLC
1) Turn off the power.
[5]
Disconnect all the cables connected to the PLC, and demount the PLC from
74(2.92")
V1+
the DIN rail.
I1+
2) Remove the extension block connector cover on
COM1
the main unit / extension block.
[6]
SLD
V2+
I2+
3) Slide the special block slide lock of the main unit
/ extension block.
COM2
4) The 4AD connector (PLC side) is connected to
SLD
the main unit / extension block connector whose
cover was previously removed.
(see the following figure.)
5) Slide back the slide lock of the main unit / exten-
V3+
sion block to attach the 4AD.
I3+
COM3
[4]
SLD
V4+
I4+
COM4
SLD
Terminal layout
4.2
Installation In Enclosure
1) Push out all DIN rail mounting hooks.
2) Fit the upper edge of the DIN
rail mounting groove onto the
DIN rail.
DIN46277 rail (35 mm (1.38")
wide)
3) Lock the DIN rail mounting
hooks while pressing the PLC
against the DIN rail.
or NO
), flammable gas, vibration or impacts, or
2
2
For installation/uninstallation, Refer to the FX
Hardware Edition.
5. Wiring (Power supply and analog input)
WIRING
PRECAUTIONS
Series PLC.
• Make sure to cut off all phases of the power supply externally before
3UC
attempting installation or wiring work.
-32MT-LT(-2) PLC.
3UC
Failure to do so may cause electric shock or damage to the product.
hook
FX
-4AD
3UC
Main unit
Series User's Manual -
3UC

Advertisement

loading

Summary of Contents for Mitsubishi Electric FX3UC-4AD

  • Page 1 Mitsubishi Electric recommend that shielded cables should be used. If NO other Effective March 2018 EMC protection is provided, then users may experience temporary loss or Specifications are subject to change without notice.
  • Page 2 Do not tighten terminal screws with a torque outside the abovementioned range. · channels) nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be V +, I +, ch represents Failure to do so may cause equipment failures or malfunctions.
  • Page 3 Mitsubishi Electric recommend that shielded cables should be used. If NO other Effective March 2018 EMC protection is provided, then users may experience temporary loss or Specifications are subject to change without notice.