Abbreviations ................11 1.10. Related documents ..............12 1.11. Document revisions ..............12 Introduction ................... 13 2.1. General information about the COM600 series ......13 2.2. COM600 product series variants and rationale ......13 2.3. Functional overview ..............14 2.4.
Page 4
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 3.4.5.7. Directional protection activation information (ACD) ............29 3.4.5.8. Device name plate (DPL) ......30 3.4.5.9. Logical node name plate (LPL) ....30 3.4.6. Data objects for measurand information ....... 31 3.4.6.1.
Page 5
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual 5.2.4.2. Controllable double point (DPC) ....49 5.2.4.3. Binary controlled step position information (BSC) ............49 5.3. Attributes ..................50 5.3.1. General information about attributes ......50 5.3.2. Server attributes ............50 5.3.3.
Copyright This document and parts thereof must not be reproduced or copied without written per- mission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.
(EMC Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN 50263 and EN 60255-26 for the EMC directive, and with the product standards EN 60255-1 and EN 60255-27 for the low voltage directive.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Operation This section covers the basic operation procedures you can carry out when transferring or activating Grid Automation Controller COM600 (later referred to as COM600) with new configurations. You are also given instructions on how to monitor and control the IEC103 commu- nication.
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 1.7. Use of symbols This publication includes warning, caution, and information icons that point out safety- related conditions or other important information. It also includes tip icons to point out useful information to the reader.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Term Description Data Set The data set is the content basis for reporting and logging. The data set contains references to the data and data attribute val- ues. Device A physical device that behaves as its own communication node in the network, for example, protection relay.
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Abbreviation Description Network Control Center Object Linking and Embedding OLE for Process Control P&C Protection & Control Programmable Logic Controller Program Organization Unit Request To Send Substation Automation Substation Configuration Description...
COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Introduction 2.1. General information about the COM600 series The COM600 product series are versatile Substation Management Units that help realize smart substation and grid automation solutions in industrial and utility distribution net- works.
• COM600F is a dedicated distribution automation controller unit that runs dis- tributed grid and feeder applications for ANSI power networks and inherits all core features of the COM600 series. 2.3. Functional overview The IEC103 OPC Server provides methods for OPC clients to exchange data with devices communicating via the IEC 60870-5-103 Master protocol.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual To create a common and protocol independent data interface between the OPC server and client, the process data from the IEC103 devices is remodeled using the IEC 61850 data modeling.
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Configuration 3.1. About this section This section guides you in the configuration tasks required before you can start using the IEC103 OPC Server. For information on the IEC 61850 data modeling, refer to COM600 User's Manual.
Page 17
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual SAB600_IEC103_Example_View.png Figure 3.2-1 Example view of SAB600 The configuration work can basically be divided into two separate tasks: building an object tree, and configuring object properties. First, you need to build an object tree. This is done by adding objects to the object tree, see 3.3.1, General information about building object tree .
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Object Description IEC103 Channel An object representing a physical communication channel. You can define up to three channels per OPC server. IEC103 IED An object representing a physical device. You should not have more than 30 devices per each channel.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual 3.3.2. Adding Gateway object To start building the object tree, add a Gateway object in the Communication structure by selecting the project name, right-click it and select New > Communication > Gate- way.
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 3.3.6. Adding Logical Device objects To add a Logical Device object: 1. Select an IEC103 Device object and right-click it. 2. Add a Logical Device object. 3. Rename the new object. The names of the Logical Device objects have to be unique.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual SAB600_IEC103_Object_Properties.png Figure 3.4.1-1 Example of object properties in the Objects Properties window 2. Select the property you want to configure. Depending on the property value type, configuring is always done either by •...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 3.4.3. Configuring IEC103 Channel properties The IEC103 Channel properties that can be configured and value ranges for them can be found in Table 3.4.3-1. The actual configuration by using SAB600 is performed as described in 3.4.1, General information about configuring objects.
Page 23
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Name Value or Value range/ Default Description Receiver Interrupt 0...255 Delay of the receiving activation in milli- Delay seconds Default: 0 Response Timeout 0...65535 Maximum waiting time of a link layer...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 3.4.4. Configuring IEC103 Device properties Table 3.4.4-1 lists the value ranges and/or default values for the IEC103 Device properties that you can define. The actual configuration by using SAB600 is performed as described in 3.4.1, General information about configuring objects.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Name Value or Value range/ Description Default Time Synchroniza- 0...65535 Time synchronization interval in seconds tion Interval Default: 15 Control Authoriza- tion Station/Remote Default: None OPC path of the station remote switch position is Switch OPC Path used with this device.
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 3.4.5.2. Single point status (SPS) Table 3.4.5.2-1 Configurable SPS properties for OPC servers Property/Para- Value or Value range/ Default Description meter Basic Common Data Common data class according to IEC...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual 3.4.5.4. Integer status (INS) Table 3.4.5.4-1 Configurable DPS properties for OPC servers Property/ Para- Value or Value range / Default Description meter Basic Common Data Common data class according to IEC...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 3.4.5.6. Protection activation information (ACT) Table 3.4.5.6-1 Configurable ACT properties for OPC servers Property/Para- Value or Value range/ Default Description meter Basic Common Data Common data class according to IEC...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual 3.4.5.7. Directional protection activation information (ACD) Table 3.4.5.7-1 Configurable ACD properties for OPC servers Property/Para- Value or Value range/ Default Description meter Basic Common Data Common data class according to IEC...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 3.4.5.8. Device name plate (DPL) Table 3.4.5.8-1 Configurable DPL properties for OPC servers Property/ Para- Value or Value range/ Default Description meter Basic Common Data Common data class according to IEC...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Indication Informa- 0...255 IEC103 indication information number tion Number Default: 105 Vendor Vendor Default: ABB A simple textstring, describing the vendor.
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Property/ Para- Value or Value range / Default Description meter Indication Function 0...255 IEC103 indication function type Type Default: 101 Indication Index 1...255 IEC103 indication index Default: 1 Indication Informa- 0...255...
Page 33
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Property/Para- Value or Value range/ Default Description meter Common Data Common data class according to IEC Class 61850 Phase A Addresses Phase A Function 0...255 IEC103 function type for phase A...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Property/Para- Value or Value range/ Default Description meter Scale and Unit Neutral Scale Default: None Scale to be used with neutral for this data object Phase Scale Default: None...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Phase CA Index 1...255 IEC103 index for phase CA Default: 3 Phase CA Informa- 0...255 IEC103 information number for phase CA...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Command ASDU 0...255 IEC103 command ASDU type Type Default: 20 Command Function 0...255 IEC103 command function type Type Default: 101 Command Informa- 0...255...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Subtype of the current data object: Same com- mand and indica- tion addresses Addresses Command ASDU 0...255 IEC103 command ASDU type...
Page 38
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Common Data Common data class according to IEC Class 61850 Subtype of the current data object: Same com- mand and indica-...
Page 39
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Scale Default: None Scale to be used with this data object...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Operation 4.1. About this section This section describes the basic operation procedures you can carry out after the IEC103 OPC Server has been configured. After this, you can, for example, monitor and control the condition of connections in an IEC103 network.
Page 41
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Eventlog_103.jpg Figure 4.3-2 Event log file Diagnostic AE Client Diagnostic events can be monitored and controlled using the Diagnostic AE Client function, see Figure 4.3-3 . Click Refresh to update the status information. To be able to receive events from a certain device, diagnostic events must be enabled for this respective device.
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 4.4. Monitoring and controlling IEC103 Channel Activity The IEC103 Channel activity can be monitored with the Online diagnostics function. You can also take a channel into use or out of use as described in this section.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual IEC103_Device_Online_diagnostics.jpg Figure 4.5-1 IEC103 Device Online diagnostics 4.6. Data object diagnostics For information on data object diagnostics, refer to COM600 User’s Manual.
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Technical reference 5.1. About this section This section provides reference information about the following issues: • IEC 61850 data modeling • Attributes • Status codes 5.2. IEC 61850 data modeling 5.2.1.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Name Type Value/ Value Mandatory Protocol informa- OPC data types range /Optional tion element Description Text VT_BSTR 5.2.2.2. Double point status (DPS) DPS represents ASDUs 1 and 2. Table 5.2.2.2-1 Double point status (DPS) information...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Table 5.2.2.4-1 Enumerated status (ENS) information Name Type Value/ Value Mandatory/ Protocol OPC data range Optional information types element stVal ENUMER- MVAL, SCL VT_I4 ATED Quality ER, OV, time...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Table 5.2.2.7-1 Device name plate (DPL) information Name Type Value/ Value Mandat- Protocol informa- OPC data types range ory/Optional tion element vendor VisibleString ASC chars [1...8] VT_BSTR hwRev VisibleString...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 5.2.3.2. Complex measured value (CMV) CMV represents ASDUs 3, 4 and 9. Name Type Value/ Value Mandat- Protocol informa- OPC data types range ory/Optional tion element cVal.mag AnalogueValue MVAL, SCL...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual 5.2.4. Data objects for controllable status information 5.2.4.1. Controllable single point (SPC) SPC represents ASDU 20. Table 5.2.4.1-1 SPC represents ASDU 20. Name Type Value/Value range Mandat- IEC103 informa-...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Table 5.2.4.3-1 Binary controlled step position information (BSC) Name Type Value/ Value Protocol informa- OPC data types range tion element ctlVal ENUMERATED stop (0) | lower (1) DCO (1:OFF,...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual 5.3.3. IEC103 Channel attributes Table 5.3.3-1 IEC103 channel attributes Name Value or Value range/ Default Description In use 0 = Not in use, the channel Data type: Integer communication is stopped...
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Name Value or Value range/ Default Description Received telegrams Incremented each time a telegram is received by the IEC103 OPC Server from the IEC103 channel. Parity errors Incremented each time a parity error is detected in a message received from the IEC103 channel.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Name Value or Value range/ Default Description Object status 1 = Re-transmit system mes- Data type: Integer sage Access: No limitations A status code, for example: Indicates the detailed information about 0 = OK (communication works the station device status.
Page 54
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual 13857 Message buffer full. The value of the Message Length parameter may be too small. 13858 Message filling error. The value of the Message Length parameter may be too small.
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Appendix 1 Interoperability list for IEC103 OPC Master Not supported Supported Supported, may need additional configuring Physical layer Electrical interface EIA RS-485 Number of loads.......for one protection equipment RS-232 EIA RS-485 standard defines unit loads so that 32 of them can be operated on one line.
Page 56
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Mode 1 (The least significant octet first), as defined in clause 4.10 of IEC 870-5-4, is used exclusively in this companion standard. Common address of ASDU (system-specific parameter) One COMMON ADDRESS OF ASDU (identical with station address)
Page 57
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual <35> Phase sequence supervision <36> Trip circuit supervision <37> I>> backup operation <38> VT fuse failure <39> Teleprotection disturbed <46> Group warning <47> Group alarm Earth fault indications in monitor direction <48>...
Page 58
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual <85> Breaker failure <86> Trip measuring system L <87> Trip measuring system L <88> Trip measuring system L <89> Trip measuring system E <90> Trip I> <91> Trip I>>...
Page 59
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual General commands in control direction <16> Auto-recloser on/off <17> Teleprotection on/off <18> Protection on/off <19> LED reset <23> Activate characteristic 1 <24> Activate characteristic 2 <25> Activate characteristic 3 <26>...
Page 60
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Current L Current L Voltage L Voltage L Voltage L Active power P Reactive power Q Frequency f Voltage L...
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Index adding channel object ....................19 Data object ..................... 20 device object ....................19 Gateway object ....................19 Logical Device object ..................20 Logical node ....................20 OPC Server object ..................19 attributes channel ......................
Page 62
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual diagnostics ..................... 43 Delta (DEL) IEC 61850 data modeling ................48 properties ....................... 34 device attributes ......................52 properties ....................... 24 device communication monitoring and controlling ................42 Device name plate (DPL) IEC 61850 data modeling ................
Page 63
1MRS752278 COM600 series, Version 5.0 IEC 60870-5-103 Master (OPC) User's Manual Protection activation information (ACD) ............46 Protection activation information (ACT) ............46 Single point status (SPS) ................44 WYE ......................48 Integer status (INS) properties ....................... 27 Logical Device object adding ......................
Page 64
COM600 series, Version 5.0 1MRS752278 IEC 60870-5-103 Master (OPC) User's Manual Logical node name plate (LPL) ................ 30 Measured value (MV) ..................31 OPC Server ....................21 Protection activation information (ACT) ............28 Single point status (SPS) ................26 WYE ......................32 Protection activation information (ACD) IEC 61850 data modeling ................