Page 1
GFK-2847R QuickPanel⁺ Operator Interface User Manual April 2016 IC755CxS06RDx (6” Display) IC755CxW07CDx (7” Display) IC755CxS10CDx (10" Display) IC755CxS12CDx (12” Display) IC755CxS15CDx (15” Display) For public disclosure...
Page 2
It is understood that GE may make changes, modifications, or improvements to the equipment referenced herein or to the document itself at any time. This document is intended for trained personnel familiar with the GE products referenced herein.
Page 3
Document Updates Description Location Added a Note to notify users that the VNC server starts 40 secs after the QuickPanel VNC Server reboots Acronyms and Abbreviations Advanced RISC Machine BBSRAM Battery-backed SRAM DRAM Dynamic Random Access Memory Frame Ground File Transfer Protocol Ground Graphical user interface HTTP...
Page 4
Safety Symbol Legend Indicates a procedure, condition, or statement that, if not strictly observed, could result in personal injury or death. Warning Indicates a procedure, condition, or statement that, if not strictly observed, could result in damage to or destruction of equipment. Caution Indicates a procedure, condition, or statement that should be strictly followed to improve these applications.
Page 5
Contact Information If you purchased this product through an Authorized Channel Partner, then contact the seller directly. General Contact Information Online technical support and GlobalCare http://support.ge-ip.com Additional information http://www.ge-ip.com/ Solution Provider solutionprovider.ip@ge.com Technical Support If you have technical problems that cannot be resolved with the information in this manual, please contact us by telephone or email, or on the web at http://support.ge-ip.com...
Page 6
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
The design is based on an Advanced RISC Machine (ARM) core describes the QuickPanel micro-processor to combine a high-resolution touchscreen operator interface with a IC755CxS06RDx, variety of communications options. Users can connect to most industrial equipment using IC755CxWxxCDx and the QuickPanel communications ports.
Note Install the QuickPanel in a well-ventilated location that is not exposed to dust, corrosive gases or liquids, rain, strong ultra-violet light or direct sunlight, and meets the following specifications. Item IC755CxS06RDx IC755CxW07CDx IC755CxS10CDx IC755CxS12CDx IC755CxS15CDx Cooling Natural convection Ambient Operating 0 to 55°C (32 to 131 °F)
Page 16
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
2 Hardware This chapter describes the QuickPanel hardware features, including physical characteristics and LED indicators. 2.1 Physical Characteristics In addition to the primary touchscreen interface, the QuickPanel Operator Interface supports a variety of communication ports. The following diagrams illustrate the physical layout of the QuickPanel Operator Interface, including locations of status LEDs, communications ports, and connectors.
Page 18
(4.5 x 3.4 in) MIC IN Serial Interface Input Power USB Host Ports 183.50 (7.22 in) (2.95 in) Battery Cover License Label Effective Screw Depth 6 mm (0.24 in) Product Nameplate IC755CxS06RDx Hardware Features GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Page 19
Status SD Card Indicator LED MICRO USB Touchscreen LINE OUT MIC IN Input USB Host Power Ports Battery Cover IC755CxW07CDx Hardware Features Note Refer to the section IC755CxW07CDx Specifications for drawing dimensions. Hardware GFK-2847R 19 For public disclosure...
Page 20
SD Card Status Indicator LED Touchscreen Input LAN1 MICRO COM2 COM1 LINE LAN2 Power Host Ports IC755CxS10CDx Hardware Features Note Refer to the section IC755CxS10CDx Specifications for drawing dimensions. GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Page 21
IC755CxS12CDx Hardware Features Note Refer to the section IC755CxS12CDx Specifications for drawing dimensions. Hardware GFK-2847R 21 For public disclosure...
Page 22
SD Card Status Indicator Touchscreen Input LINE LAN2 LAN1 MICRO COM2 COM1 Power Host Ports IC755CxS15CDx Hardware Features Note Refer to the section IC755CxS15CDx Specifications for drawing dimensions. GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Operation status • Ethernet Port operation 2.2.1 Operation Status LEDs The QuickPanel has one tri-color LED that provides visual operation status indication for IC755CxS06RDx, IC755CxW07CDx, the and IC755CxSxxCDx units. QuickPanel State LED State Amber, solid Operating system starting Green, solid...
Page 24
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
3 Software This chapter provides QuickPanel software information and procedures to perform the most common tasks. 3.1 Operating System Refer to http://windows. The QuickPanel operating system (OS), Microsoft Windows Embedded Compact 7, is a microsoft.com. full 32-bit OS with graphical user interface (GUI). It is stored in flash memory and copied to a block of DRAM for execution.
3.4 Copy Project to SD Card The custom utility Copy Project to SD Card transfers Proficy Machine Edition View and Control projects between compatible QuickPanel units using SD cards. Before disconnecting power, verify that the copy or update operation is complete (no busy message or wait cursor).
3.6 FTP Server The File Transfer Protocol (FTP) server included with the QuickPanel unit supports standard (RFC 959). It does not support Secure File Transfer Protocol (SFTP) or implicit FTPS, which uses different ports and is based on Secure Shell (SSH) rather than Secure Sockets Layer (SSL).
3.7 HTTP Server The HyperText Transfer Protocol (HTTP) server included with the QuickPanel supports standard (RFC 2616). The HTTP server is configured with the Quick Panel+ Setup Tool. By default, the server is not enabled. Once enabled, a background program will run, waiting for clients to connect.
QuickPanel OS Utilities Settings Tool Support builds, these operations were QuickPanel Product Firmware Build only supported using the DIP IC755CxS06RDx (6" Display) 01 (initial release) Switch settings. IC755CxW07CDx (7” Display) IC755CxS10CDx (10” Display) IC755CxS12CDx (12” Display) IC755CxS15CDx (15” Display) The tool operation buttons for each utility only respond to a double-tap finger gesture. It will not accept any keyboard or mouse clicks, finger simulator-based inputs, or click inputs from any remote touch-based device.
If the current firmware build version on the QuickPanel is any of the following, refer to the section Firmware Upgrade for Specific Build Version: • Build 3 or below for IC755CxS06RDx (6” Display) • Build 23 or below for IC755CxW07CDx (7” Display) Attention •...
Page 31
From the QuickPanel OS Utilities Settings window , select Firmware Upgrade, then double-tap Upgrade. The operator interface guides the operator through the firmware upgrade process. After successful upgrade, restart the device. Download the project and install any site-specific tools, including third party tools, on the device.
3.9.2 Firmware Upgrade for Specific Build Version The following procedure is applicable to the following QuickPanel display units: • QuickPanel IC755CxS06RDx (6” Display) with build 3 or below • QuickPanel IC755CxW07CDx (7” Display) with build 23 or below • QuickPanel IC755CxS10CDx (10"...
3.9.3 Bypass Startup Programs This utility functions the same The Bypass Startup Programs utility enables the operator to choose the gesture-based as disabling or enabling the feature or DIP Switch (Use DIP Switch) feature to perform the Force Startup operation. Don’t startup Program functionality using DIP Switch ➢...
Page 34
If Enable is double-tapped, the startup window displays and all startup programs are enabled to run . If Disable is double-tapped, the startup window displays . Click Don’t run Startup programs to stop all startup programs from running . If Use DIP Switch is selected, Don’t run StartUp Programs displays on the startup window based on the position of DIP Switch 2.
3.9.4 Reset Enhanced Security The QuickPanel Operator Interface is configured using the Proficy Machine Edition (PME) application. Using the PME Enhanced Security feature, users can specify password protection for any network-connected QuickPanel device to perform certain operations, such as the download operation. Every operation to connect to the device requires a password.
3.9.5 Enable or Disable SNMP Agent The QuickPanel Operator Interface can be enabled as a Simple Network Management Protocol (SNMP) Agent with the capability to communicate with SNMP Managers for notification of Traps and responding to Query HMI Tag values. Since it is designed to run over a public network, SNMP communication is disabled by default on the QuickPanel device for security reasons.
Page 37
Note Any failure or errors while enabling or disabling the SNMP service would be communicated to the user through a dialog box. ➢ ➢ To disable the SNMP Agent From the Start menu, select Programs, System, and QuickPanel OS Utilities Settings Tool to display the QuickPanel OS Utilities Settings window.
3.10 Display Screen Sensitivity Tool The QuickPanel 7”, 10”, 12”, and 15” display units use capacitive screen technology that is far more responsive than the previously used resistive touchscreen technology. Resistive screens required the operator to firmly press down on the resistive overlay for a response.
3.11 Launch Application The Launch application window contains the shortcuts to launch some of the major QuickPanel Operator Interface applications. ➢ ➢ To launch an application From the Start menu , select Programs, System , and Launch Application. From the Launch Application window, tap an application icon to start the application.
3.12 VNC Server The VNC Server enables remote, visual connectivity to the QuickPanel Operator Interface from a laptop computer or a mobile device through the remote VNC Viewers. User authentication of the VNC Server in the QuickPanel is determined by the configuration of the Enhanced Security feature on the device.
3.13 Battery Life Prediction The QuickPanel Operator Interface provides an estimated lifespan of the battery in the device. To display the battery life prediction, the current time on the QuickPanel device must be set. If a battery is not present, the QuickPanel BatteryStatus tab cannot provide battery life prediction.
Page 42
After setting the current time, open the QuickPanel Setup Tool, and select the BatteryStatus tab to display the correct battery life prediction information. Example of Battery Life Prediction Displayed After Current Time Set If the battery was replaced or removed on the QuickPanel , QuickPanel Setup Tool BatteryStatus displays two possible scenarios related to the battery.
Page 43
If the option The battery is not present is selected, a message displays stating that battery life cannot be predicted without a battery installed on the device. Battery is Not Present Message If the option The battery was replaced is selected, enter the date of when the battery was first used in a QuickPanel device.
Page 44
Close and re-open the QuickPanel Setup Tool dialog box to display the battery life prediction information. Close and Reopen Message Battery Life Prediction Example after Battery Replacement GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
3.14 Simple Network Management Protocol (SNMP) The SNMP is an application–layer protocol defined by the Internet Architecture Board (IAB) in RFC1157 that is used for exchanging management information between network devices. It is a part of the Transmission Control Protocol/Internet Protocol (TCP/IP) suite. The QuickPanel Operator Interface is enabled as an SNMP Agent with the capability to communicate with SNMP Managers (software tools run independently and are not part of...
Page 46
The following figure displays the MIB tree structure and the private enterprise number allocated by the Internet Assigned Numbers Authority (IANA) for the GE SNMP products and OID for the QuickPanel MIB: OID for GEIP node: .1.3.6.1.4.1.24893 OID for qppMIB node: .1.3.6.1.4.1.24893.1.5.2.1.1 It is highly recommended that you pre-load GE MIBs (GEIP-SMI.txt and GEIP-PRODUCTS-MIB.
Page 47
The following figure displays the HMI Alarms notification (TRAP information) with alarm objects as part of the Alarm Record. The SNMP Manager is notified with the TRAP information when alarms are generated on the HMI running on a QuickPanel device. OID for Alarm Trap: .1.3.6.1.4.1.24893.1.5.2.1.1.10 Software GFK-2847R 47...
Page 48
The following figure displays the list of HMI Tags that the SNMP Manager can query to retrieve live values from the HMI running on a QuickPanel device. Note The list of all HMI tags are populated within the hmiTags node of MIB tree and the HMI Tag access level is currently restricted to Read-only for the SNMP Manager.
The following sections provide the procedures to enable and configure the QuickPanel device to operate as a SNMP Agent and establish communication with a SNMP Manager. • Configure Trap Destinations • Enable or Disable SNMP Agent Export MIB to SD Card •...
With the SNMP Agent is enabled on the QuickPanel device, export the QuickPanel Management Information Base (MIB) QuickPanelMIB.mib file to a SD Card. It is highly recommended that you pre-load GE MIBs (GEIP-SMI.txt and GEIP-PRODUCTS-MIB. txt in sequence) prior to loading the QuickPanelMIB.
A dialog box displays when the copy is successful or if a failure occurs. 3.14.4 Load MIB into SNMP Manager After successfully exporting the MIB to a SD Card, archive the QuickPanel MIB file to a folder on a machine running with SNMP Manager. ➢...
This enables you to map to the DISPLAYSTRING data type in the SNMP communication as well. For example, for the GE SRTP driver, you can override the IO Address of LREAL variable LREALVar data type as %R100[INT]. This maps LREALVar to DISPLAYSTRING in the MIB file.
3.14.6 Establish SNMP Communication SNMP communication requires that both the QuickPanel device and the SNMP Manager running on a machine are connected on a valid Ethernet network. Attention ➢ ➢ To establish SNMP communication with the QuickPanel device Download the Project to the network connected QuickPanel device and start Runtime.
Page 54
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Customer Care. Before initial powerup, inspect the unit for loose or damaged components. If damage is found (such as bent component leads or loose components), contact GE Intelligent Platforms for additional instructions. Do not apply power to the unit if it has visible damage.
Page 56
QuickPanel Operator Interface Battery (Qty 1) (pre-installed) Serial Port Connector (Qty 1) Power Connector (Qty 1) Mounting Brackets (Qty 4) Protective Sheet (Qty 1) (not shown) Gasket (Qty 1) (not shown, pre-installed) IC755CxWxxCDx Example Package Contents GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
4.2 Basic Setup The QuickPanel Operator Interface is shipped ready for use after initial configuration. To power up the unit, connect a dc power supply using the supplied quick-connect plug. Depending on the application, you may also want to connect and configure optional input devices, communications ports, and expansion adapters.
4.3 Initial Startup You will need the following: • Safety Extra Low Voltage (SELV) and Limited Energy Circuit or SELV and Class 2 dc power supply. • The power terminal block is supplied with the product. For voltage and requirements, refer to the Input Power specifications in the table, General Specifications.
To download an application to a QuickPanel Operator Interface, set up a data link between the unit and the development workstation. Refer to the section, Ethernet for IC755CxS06RDx, IC755CxWxxCDx and IC755CxSxxCDx, and the PME online help, Downloading a Machine Edition Project. Pre-installation Checks...
4.5 Firmware Updates Update the unit to the most recent released version of the firmware, with the latest feature are available on the upgrades and issues addressed. Firmware updates for the QuickPanel Support website. Note The firmware update will remove the application and change the IP Address of the QuickPanel Operator Interface.
5 Mounting and Installation This chapter provides the following procedures to mount and install the QuickPanel Operator Interface: • Protective Sheet Installation • Mounting Location • Panel Mounting • VESA Arm Mounting • Battery Installation and Replacement • Connectors 5.1 Protective Sheet Installation ➢...
5.2 Mounting Location Refer to the section, When mounting the QuickPanel Operator Interface, make sure the mounting area allows Environmental Specifications. room to insert and remove the SD card, cables, and mounting brackets. Select a location that allows natural convection air flow from bottom to top of the QuickPanel enclosure.
• One #2 Phillips head screwdriver • Mounting brackets (supplied) The mounting holes for IC755CxS06RDx, IC755CxW07CDx, and IC755CxS10CDx are located on the top and bottom sides of the unit. IC755CxS06RDx Mounting Holes IC755CxW07CDx Mounting Holes Mounting and Installation...
Page 64
IC755CxS10CDx Mounting Holes The IC755CxS12CDx and IC755CxS15CDx mounting holes are located on the top, bottom, and sides of the unit. IC755CxS12CDx Mounting Holes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Page 65
IC755CxS15CDx Mounting Holes Mounting and Installation GFK-2847R 65 For public disclosure...
5.4 Mounting and Installation Procedure Observe the following guidelines to properly mount and install the QuickPanel Operator Interface: • The enclosure should be of metal material. • The metal enclosure panel should ensure proper thickness and rigidity suitable to minimize impact to the QuickPanel unit.
Page 67
Insert the hook of the mounting bracket into the mounting hole as displayed in the following figure. Tighten the screws on the mounting bracket in a clock-wise direction. Torque Range for Mounting Clamp Screws Display Unit Torque Range IC755CxS06RDx 0.3 Nm (2.66 in-lb) IC755CxW07CDx 0.3 Nm (2.66 in-lb) IC755CxS10CDx 0.7 Nm (6 in-lb) IC755CxS12CDx 1.0 to 1.2 Nm (8.9 to 10.6 in-lb)
(displayed in the following figures). manual for instructions. The mounting holes for IC755CxS06RDx and IC755CxW07CDx attach with M4 screws that are 6 mm (0.24 in) or less in length. The mounting holes for IC755CxSxxCDx attach with M4 screws that are 8 mm (0.32 in) or less in length.
5.6 Battery Installation and Replacement Batteries may present a risk of fire, explosion, or chemical burn if mistreated. Do not crush, disassemble, short-circuit, or dispose of in fire. Use of batteries not specified for use with the Warning QuickPanel product may present a risk of fire or explosion.
5.6.1 IC755CxS06RDx ➢ ➢ To install or replace the battery for IC755CxS06RDx Replace the battery for the IC755CxS06RDx only with GE battery part number IC755ACCBATT. Caution Remove the battery cover by pressing down while sliding outward. IC755CxS06RDx Battery Cover Removal Connect the battery harness connector to the header, noting keyed orientation.
Page 71
Wrap the harness connector around to match the following figure. Do not let the harness connector go above the tab. Harness Connector Orientation Slide the battery cover into place, taking care not to pinch the harness connector. Mounting and Installation GFK-2847R 71 For public disclosure...
5.6.2 IC755CxW07CDx ➢ ➢ To install or replace the battery for the IC755CxW07CDx Replace the battery for the IC755CxW07CDx only with GE battery part number IC755ACCBATT. Caution Remove the battery cover by pressing down while sliding outward. IC755CxW07CDx Battery Cover Removal Connect the battery harness connector to the header, noting keyed orientation.
Page 73
Wrap the harness connector around to match the following figure. Do not let the harness connector go above the tab. Harness Connector Orientation Slide the battery cover into place, taking care not to pinch the harness connector. Mounting and Installation GFK-2847R 73 For public disclosure...
5.6.3 IC755CxSxxCDx ➢ ➢ To install or replace the battery for the IC755CxSxxCDx Replace the battery for the IC755CxSxxCDx only with GE battery part number IC755ACCBATTNL. Caution Remove the screws (quantity 7) from the back cover. IC755CxSxxCDx Screw Locations (Back Cover) Gently press on either side tab to release the back cover.
Page 75
The battery will be exposed on the back of the unit. Battery Part Number IC755ACCBATTNL IC755CxSxxCDx Battery Gently remove the coin battery and replace with a new one, noting the polarity of the battery. Replace the battery cover and tighten all screws to 0.5 Nm (4.4 in-lb). Mounting and Installation GFK-2847R 75 For public disclosure...
5.7 Connectors 5.7.1 Power Connector Pin-out for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx Refer to the section Connecting Connector: Terminal Euro (Tyco Electronics 284539-3) Input Power. Mating Connector: (Tyco Electronics 284510-3) Pin # Signal Name Pin-out +24 V dc † † IC755CxSxxCDx supports both +12 V dc or +24 V dc IN 5.7.2 Ethernet for IC755CxS06RDx, IC755CxW07CDx,...
Page 77
5.7.2.2 IP Address Setting The QuickPanel Operator Interface provides two methods to set an IP address: • DHCP (Dynamic Host Configuration Protocol) The network server assigns an IP address during QuickPanel initialization. There must be a DHCP server on the connected network for a valid IP address to be assigned.
Connectors: Euro Terminal (Tyco Electronics 284539-5) Mating Connectors: Tyco Electronics 284510-5 Serial Port COM1 Details Interface: RS-232 COM1 Pin Details Signal Name Pin # SGND Pin 5 Pin 1 IC755CxS06RDx Serial Port COM1 Pin-out GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Page 79
5.7.3.2 IC755CxW07CDx Adhere to the following guidelines: • A terminal block is supplied with the unit. • The mating terminal block supports stranded 30 to 14 AWG (0.05 to 2.00 mm wires. • At a minimum, the cable must be rated for 75°C (167 °F) or more. •...
Page 80
5.7.3.3 IC755CxSxxCDx For an IC755CxS12CDA serial Adhere to the following guidelines: port, refer to • Terminal blocks are supplied. Appendix C IC755CxS12CDA • The mating terminal blocks support stranded 30 to 14 AWG (0.05 to 2.00 mm Serial Port Details. wires.
Page 81
COM1 DIP Switch Setting for RS-232C DIPSW ON/OFF DIPSW ON/OFF Serial Port COM2 Details Interface: RS-232C/485 (default is RS-485 Half-duplex) COM2 Pin Details RS–232C RS–485 Signal Name Signal Name Pin # Signal Name (Full-duplex † (Half-duplex † DATA+ ‡ TXD+ DATA- ‡...
Page 82
Example of Full-duplex (RS–422 Mode) Connection COM2 DIP Switch Setting for RS–422 DIP SW ON/OFF DIP SW ON/OFF Example of Half-duplex (RS–485 Mode) Connection GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Page 83
COM2 DIP Switch Setting for RS–485 DIPSW ON/OFF DIPSW ON/OFF Mounting and Installation GFK-2847R 83 For public disclosure...
5.7.4 Universal Serial Bus (USB) Ports 5.7.4.1 USB Host Port Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx The QuickPanel has two full-speed USB 2.0 host ports. A variety of third party USB peripheral devices are also available. Each connected USB device requires a specific driver.
• RT–2870 • RT–3070 • RT–3071 • RT– 3072 5.7.5 Audio (LINE OUT) Details for IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx Interface: LINE OUT (stereo) Number of Ports: One Connectors: φ3.5 mm jack Maximum output level: 1 Vrms Signal Name Pin #...
SD Card port. SD/SDHC memory cards are supported. The SD card slot is spring-loaded for easy insertion and removal. Note Micro SD slot is not supported on the 6” display unit (IC755CxS06RDx). Connectors: SD card slot (push in-push out method)
Page 87
IC755CxSxxCDx SD Card Location Mounting and Installation GFK-2847R 87 For public disclosure...
Page 88
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
This could damage the touchscreen display. Caution Note IC755CxS06RDx (6” display) is an Analog Resistive touch display that does not support two-point touch capability. Single point gestures such as swipe, pan, and double-tap are supported.
6.1.2 Display Backlight Configuration ➢ ➢ To configure the display backlight Open the QuickPanel Setup Tool and select the Backlight tab to display the Backlight Display Properties window. Set the backlight to automatically turn off in a specific amount of time. Select Automatically turn off the backlight .
Select the TouchPanel tab. Select Recalibrate Touch Screen. Select Recalibrate Touch Sensor. Note During IC755CxS06RDx or IC755CxW07CDx touchscreen sensor re-calibration, the user is prompted to activate a switch located in the battery compartment. This is not applicable to any other display units.
6.2 Keyboard Configuration The QuickPanel Operator Interface can be configured to use either or both a hardware keyboard and a software emulation keyboard as operator data input devices. Typically, an optional external hardware keyboard is used when in development mode, while the included Soft Input Panel (SIP) is more applicable in an operational environment.
6.4 Printing USB-connected printers will violate the electrical compliance ratings. They can only be used for maintenance and are not supported as a standard service. Warning The QuickPanel Operator Interface supports printing with PCL v5 compatible laser and inkjet printers. The printer can be connected by either USB (on models with USB ports) or by a network shared printer over Ethernet.
6.5 Memory 6.5.1 DRAM Memory The QuickPanel Operator Interface is equipped with Dynamic RAM (DRAM). Part of the DRAM is reserved for the Windows operating system and is not accessible by user applications. The remaining memory is split between two functions: an object store for temporary file storage and the main memory for running programs.
6.5.2 Memory Allocation Modification ➢ ➢ To change the memory allocation From the Control Panel, double-tap System to display the System Properties window. From the Memory tab, drag the slider bar to divide into Storage and Program memory. The amount of memory allocated to and used by each area is displayed in the window.
Page 96
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
7 Secomea Security (Optional) 7.1 Secomea Configuration Tool The SiteManager ™ and its Secomea SiteManager software (also known as the Secomea Configuration tool) is related GateManager ™ installed on QuickPanel products. The Secomea Configuration tool enables the user to LinkManager ™...
7.2 Secomea Products Activation and deployment of The available Secomea SiteManager (embedded on QuickPanel ), GateManager, and the Secomea product features LinkManager products are described as follows: is optional. SiteManager, SiteManager is a device-monitoring front-end feature for multiple industrial devices on GateManager, and a location.
Page 99
Secomea Products used with QuickPanel in Application Secomea Security (Optional) GFK-2847R 99 For public disclosure...
Page 100
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Appendix A Product Certifications and Installation Guidelines The QuickPanel Operator Interface is intended for use in industrial environments and, when properly installed, shall comply with the agency approvals listed in this document. Agency Approvals Note The agency approvals listed in the following table and on the Declaration of Conformities are believed to be accurate;...
Page 102
Conditions of Safe Use for Installation in Hazardous Locations The following information applies to products bearing the UL marking for Hazardous areas and the ATEX marking for Zone 2 explosive atmospheres: Suitable for use in Class I Division 2 Groups A, B, C, D (applicable to 7'', 10'', 12'', and 15'' Display units).
Page 103
Changes or modifications to this unit that are not expressly approved by GE Intelligent Platforms could void the user’s authority to operate the equipment.
Page 104
EMC Installation and Operation Considerations This equipment is intended for industrial use only and complies with a minimum level of EMC performance as defined by EN 61000-6-2 and EN 61000-6-4 standards. To meet these requirements, the following installation and operation considerations were taken into account: •...
Operator Interface Part Numbers Description Part Number QuickPanel 6” Color TFT with Resistive Touch Screen, GE Monogram Bezel , 24 V dc Powered IC755CSS06RDA IC755CBS06RDA QuickPanel 6” Color TFT with Resistive Touch Screen, Blank Bezel , 24 V dc Powered QuickPanel 6”...
Page 106
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...
Appendix C IC755CxS10CDx, IC755CxS12CDA, and IC755CxS15CDx Serial Port Details Adhere to the following guidelines: • A terminal block is supplied. • The mating terminal block supports stranded 30 to 14 AWG (0.05 to 2.00 mm wires. • At a minimum, the cable must be rated for 75°C (167 °F) or more. •...
Page 108
Notes GFK-2847R QuickPanel⁺ Operator Interface User Manual For public disclosure...