A.1.1 Flexanalog Items - GE Multilin g60 Instruction Manual

Ur series generator protection system
Hide thumbs Also See for Multilin g60:
Table of Contents

Advertisement

APPENDIX A
Appendices
APPENDI X A Fl e xAnal o g and Fl e xI n t e ger Par a met e r s A.1Parameter Lists
Table A–1: FLEXANALOG DATA ITEMS (Sheet 1 of 23)
ADDRESS
FLEXANALOG NAME
5728
Stator Diff Iad
5730
Stator Rest Iar
5732
Stator Diff Ibd
5734
Stator Rest Ibr
5736
Stator Diff Icd
5738
Stator Rest Icr
5744
Stator Gnd Vn 3rd
5746
Stator Gnd Vn+V0 3rd
5748
Stator Gnd V0 3rd
5760
Sns Dir Power 1
5762
Sns Dir Power 2
5792
RGF 1 Igd Mag
5794
RGF 1 Igr Mag
5796
RGF 2 Igd Mag
5798
RGF 2 Igr Mag
5800
RGF 3 Igd Mag
5802
RGF 3 Igr Mag
5804
RGF 4 Igd Mag
5806
RGF 4 Igr Mag
5808
RGF 5 Igd Mag
5810
RGF 5 Igr Mag
5812
RGF 6 Igd Mag
5814
RGF 6 Igr Mag
5856
Freq Rate 1 Value
5860
Freq Rate 2 Value
5864
Freq Rate 3 Value
5868
Freq Rate 4 Value
6144
SRC 1 Ia RMS
6146
SRC 1 Ib RMS
6148
SRC 1 Ic RMS
6150
SRC 1 In RMS
6152
SRC 1 Ia Mag
6154
SRC 1 Ia Angle
6155
SRC 1 Ib Mag
6157
SRC 1 Ib Angle
6158
SRC 1 Ic Mag
6160
SRC 1 Ic Angle
6161
SRC 1 In Mag
6163
SRC 1 In Angle
6164
SRC 1 Ig RMS
6166
SRC 1 Ig Mag
6168
SRC 1 Ig Angle
6169
SRC 1 I_0 Mag
6171
SRC 1 I_0 Angle
6172
SRC 1 I_1 Mag
GE Multilin
UNITS
DESCRIPTION
Amps
Stator differential phase A current (Iad)
Amps
Stator restraint phase A current (Iar)
Amps
Stator differential phase B current (Ibd)
Amps
Stator restraint phase B current (Ibr)
Amps
Stator differential phase C current (Icd)
Amps
Stator restraint phase C current (Icr)
Volts
Stator ground Vn third harmonic voltage
Volts
Stator ground Vn+V0 third harmonic voltage
Volts
Stator ground V0 third harmonic voltage
Watts
Sensitive directional power 1 actual value
Watts
Sensitive directional power 2 actual value
Amps
Restricted ground fault 1 differential ground current magnitude
Amps
Restricted ground fault 1 restricted ground current magnitude
Amps
Restricted ground fault 2 differential ground current magnitude
Amps
Restricted ground fault 2 restricted ground current magnitude
Amps
Restricted ground fault 3 differential ground current magnitude
Amps
Restricted ground fault 3 restricted ground current magnitude
Amps
Restricted ground fault 4 differential ground current magnitude
Amps
Restricted ground fault 4 restricted ground current magnitude
Amps
Restricted ground fault 5 differential ground current magnitude
Amps
Restricted ground fault 5 restricted ground current magnitude
Amps
Restricted ground fault 6 differential ground current magnitude
Amps
Restricted ground fault 6 restricted ground current magnitude
Hz/s
Frequency rate of change 1 actual value
Hz/s
Frequency rate of change 2 actual value
Hz/s
Frequency rate of change 3 actual value
Hz/s
Frequency rate of change 4 actual value
Amps
Source 1 phase A current RMS
Amps
Source 1 phase B current RMS
Amps
Source 1 phase C current RMS
Amps
Source 1 neutral current RMS
Amps
Source 1 phase A current magnitude
Degrees
Source 1 phase A current angle
Amps
Source 1 phase B current magnitude
Degrees
Source 1 phase B current angle
Amps
Source 1 phase C current magnitude
Degrees
Source 1 phase C current angle
Amps
Source 1 neutral current magnitude
Degrees
Source 1 neutral current angle
Amps
Source 1 ground current RMS
Degrees
Source 1 ground current magnitude
Amps
Source 1 ground current angle
Degrees
Source 1 zero-sequence current magnitude
Amps
Source 1 zero-sequence current angle
Degrees
Source 1 positive-sequence current magnitude
G60 Generator Protection System
A.1 PARAMETER LISTS

A.1.1 FLEXANALOG ITEMS

A-1