hit counter script
GE LightSpeed 16 Product Data Sheet

GE LightSpeed 16 Product Data Sheet

Ct scanner system

Advertisement

g
Product Data Sheet – rev 4.2
July 4th 2003
Page 1
Introduction
16
The LightSpeed
CT Scanner with
TM
Xtream
technology is the next step in
GE's CT Continuum and its award-
winning LightSpeed CT platform. The
16
LightSpeed
CT Scanner routinely
acquires 16 sub-millimeter slices in one
rotation, at a scan speed of 0.5 seconds.
As with the very first LightSpeed product
16
introduction, the LightSpeed
Designed for Six Sigma (DFSS
methodology in all aspects of
manufacturing and engineering.
16
LightSpeed
is available both as a new
system or as a cost-effective upgrade to
an existing LightSpeed system.
Primary Benefits
• Routine use of sub-millimeter slices
without
image
noise
compromise.
• Small
lesion
and
small
assessments – pancreas, liver or circle
of willis, renal arteries, coronary arteries
and peripheral vascular arteries.
• The 6.3 MHU Performix X-Ray Tube
demonstrates the highest reliability and
delivers the power you need for image
quality. The Performix Tube now comes
standard with a one-year, non pro-rated
warranty.
* Option
LightSpeed
CT Scanner System
• microVoxel
reformatted 2D resolution through the
optimum choice of sub-millimeter slice
thickness and reconstructed voxel size.
• Unmatched Volume Image Quality
specification in all planes (sagittal, coronal
and axial): 15.4 lp/cm @ 0% MTF @ 0.5
sec. Rotation
• HiLight
utilizes
deliver consistent image quality with its
TM
)
21,888 individual elements: 16 rows of
0.625mm thickness and 8 rows of 1.25mm
thickness
• Xtream
workflow design, breaks through existing
limits on speed, image quality and flexibility
to provide an optimized workflow solution
from acquisition to final report.
• Lowest dose acquisition using SmartmA,
an automatic modulation technique and DLP
display that tells the operator the dose
before the scan starts.
or
coverage
• HyperPlane
tackles the inherent issues with fast, high
pitch helical scanning by reducing helical
vessels
artifacts and dose, and optimizing the slice
profile.
• CrossBeam
solves the technical challenge of cone beam
artifacts.
• Large breadth of Advanced Software
Applications: Advanced Lung Analysis, CT
Colonography, Advanced Vessel Analysis,
Brain and Body Perfusion, Cardiac Analysis,
16
With Xtream
TM
imaging improves 3D and
TM
Matrix II Detector is designed to
TM
technology, a revolutionary new
TM
reconstruction algorithm
TM
reconstruction algorithm
GE Medical Systems-America
Milwaukee, USA - Fax: 1 414 544 3384
GE Medical Systems-Asia:
Tokyo, Japan - Fax: 81 425 85 5490
Hong Kong - Fax: 852 2559 3588
GE Medical Systems-Europe
Cardiac Function, SmartScore Pro and
Advantage Sim.
• Compact system design of the
16
LightSpeed
allows for installation in only
28m² (302 square feet).
• Productivity features designed for the CT
Technologist: In-Room Start, Remote
Gantry Tilt, Breathing Lights with countdown
timer, Gantry Controls mounted on all four
corners of the gantry and an Integrated IV
Pole at the foot of the table.
• 1700 mm scannable range for full body
scans.
• 254 GB Disk (system, image, scan disks)
stores up to 250,000 512
scan data files.
• Cardiac acquisition with Segment, Burst
and Burst Plus enable you to scan patients
with heart rates from 40 to 110 BPM, and
provide for temporal resolution up to 65
ms.
• Color Coding for Kids, winner of a
National Heroes Award from the Emergency
Medical Services for Children, provides
pediatric scan protocols based on the
TM
Broselow-Luten
Pediatric System. This
Color Coding system is incorporated into the
protocol selection on the operator's console
and is designed to facilitate pediatric
emergency care and reduce medical errors.
TM
• VariViewer
: provides an interactive axial
review mode that can change the slice
thickness reconstruction instantaneously,
resulting in the ability to "scan thin and view
thick."
Clinical Performance
Chest / Abdomen / Pelvis
TM
Coverage
Rotation
Mode
Pitch
mA
mAs
Speed
Scan Time
2
images and 2881
600 mm
0.5 sec.
16 x 0.625 mm
1.75:1
420
210
35 mm/s
17.1 seconds

Advertisement

Table of Contents
loading

Summary of Contents for GE LightSpeed 16

  • Page 1 Broselow-Luten Pediatric System. This GE’s CT Continuum and its award- Color Coding system is incorporated into the • Unmatched Volume Image Quality winning LightSpeed CT platform. The protocol selection on the operator’s console...
  • Page 2: Main Features

    LightSpeed family - true interactive CT reminder of time until X-ray initiation. and exam speed. technology. • SmartHelical GE proprietary, non-linear interpolation algorithms, balance slice Interactive CT embodies a variety of design Main Features profile, helical pitch, image noise and choices all striving to enhance operator and required technique.
  • Page 3 GE Medical Systems-America Milwaukee, USA - Fax: 1 414 544 3384 GE Medical Systems-Asia: LightSpeed Tokyo, Japan - Fax: 81 425 85 5490 Product Data Sheet – rev 4.2 Hong Kong - Fax: 852 2559 3588 July 4th 2003 GE Medical Systems-Europe...
  • Page 4: System Specifications

    GE Medical Systems-America Milwaukee, USA - Fax: 1 414 544 3384 GE Medical Systems-Asia: LightSpeed Tokyo, Japan - Fax: 81 425 85 5490 Product Data Sheet – rev 4.2 Hong Kong - Fax: 852 2559 3588 July 4th 2003 GE Medical Systems-Europe...
  • Page 5 CT Number Scale: -1024 to 3071 HU 11.25 18.75 27.5 for adult and pediatric exams. There are Helical Reconstruction Times: four selection tabs to select: GE, User, Service and Most Recent Patient.  Reconstruction time as fast 6 Copy/Paste is supported for easy Helical Scan Parameters images per second modification and copying of protocols.
  • Page 6 2,881 contiguous rotations (with up to High-Contrast Spatial Resolution 1,500 images in one series). On GE Performance phantom: (The following chart assumes 120-second helical with 5-sec IGD) Standard Algorithm * Option...
  • Page 7 16 rows of scan Noise: data. There are five reconstruction modes • Minimum ISD with table movements of On either an AAPM water phantom or GE available for creating images from the 0 - 10 mm: 1.0 sec. Quality Assurance phantom: multi-slice scan data (1i, 2i, 4i, 8i, and 16i).
  • Page 8 250 milliseconds. typical clinical conditions. High Contrast Spatial Resolution: Prospective Multiple Reconstruction Standard Scans: On GE Performance phantom: (PMR): Up to 3 sets of reconstructions can be pre-programmed as part of the scan Standard Algorithm protocol prior to acquisition. The operator...
  • Page 9: User Interface

    Noise: or any angle from 0° - 359° (manually selected). The Exam Rx desktop environment provides On either an AAPM water phantom or GE the clinical tools necessary for comfortable, Quality Assurance phantom: Axial scan prescription lines indicate scan efficient control of patient studies.
  • Page 10 GE Medical Systems-America Milwaukee, USA - Fax: 1 414 544 3384 GE Medical Systems-Asia: LightSpeed Tokyo, Japan - Fax: 81 425 85 5490 Product Data Sheet – rev 4.2 Hong Kong - Fax: 852 2559 3588 July 4th 2003 GE Medical Systems-Europe...
  • Page 11 GE Medical Systems-America Milwaukee, USA - Fax: 1 414 544 3384 GE Medical Systems-Asia: LightSpeed Tokyo, Japan - Fax: 81 425 85 5490 Product Data Sheet – rev 4.2 Hong Kong - Fax: 852 2559 3588 July 4th 2003 GE Medical Systems-Europe...
  • Page 12: Image Display

    Screening orientation and window/level with each data Console can directly print to a postscript set. printer such as the GE Color Printer available • Curved Volume Of Interest as an option. • Window/Level values may be: • Protocol Management and Loading •...
  • Page 13: Industry Standards

    • 3M-952 Standard • Elevation Speeds: 5 mm/sec and 40 supporting the DICOM 3.0 protocol for mm/sec network send, receive and pull/query. GE System Components • Horizontal Range: 170 cm systems that support this interoperability include CT HiSpeed CT/i, X/i, NX/i, QX/i, •...
  • Page 14: Host Computer

    GE Medical Systems-America Milwaukee, USA - Fax: 1 414 544 3384 GE Medical Systems-Asia: LightSpeed Tokyo, Japan - Fax: 81 425 85 5490 Product Data Sheet – rev 4.2 Hong Kong - Fax: 852 2559 3588 July 4th 2003 GE Medical Systems-Europe...
  • Page 15: Compatible Options

    • LCD Monitor (B7858LC) • Direct network connection; multi-suite Scanner System does not require any power ethernet card not required for gateway out of • GE Color Printer (E7014LA) conditioning equipment to be used in suite conjunction with the PDU. Regulators are not •...
  • Page 16: Warranty

    GE Medical Systems-America Milwaukee, USA - Fax: 1 414 544 3384 GE Medical Systems-Asia: LightSpeed Tokyo, Japan - Fax: 81 425 85 5490 Product Data Sheet – rev 4.2 Hong Kong - Fax: 852 2559 3588 July 4th 2003 GE Medical Systems-Europe...
  • Page 17 GE Medical Systems-America Milwaukee, USA - Fax: 1 414 544 3384 GE Medical Systems-Asia: LightSpeed Tokyo, Japan - Fax: 81 425 85 5490 Product Data Sheet – rev 4.2 Hong Kong - Fax: 852 2559 3588 July 4th 2003 GE Medical Systems-Europe...
  • Page 18 GE Medical Systems-America Milwaukee, USA - Fax: 1 414 544 3384 GE Medical Systems-Asia: LightSpeed Tokyo, Japan - Fax: 81 425 85 5490 Product Data Sheet – rev 4.2 Hong Kong - Fax: 852 2559 3588 July 4th 2003 GE Medical Systems-Europe...

Table of Contents

Save PDF