Bypass fiow-through humidifier
Hide thumbs Also See for HE220A,B:

Advertisement

APPLICATION

The HE220A,B and HE260A,B Bypass Flow-through
Humidifiers use the warm air furnace blower to provide
humidification for the whole house. The humidifiers work with
virtually any Honeywell humidity control, but use the
Honeywell Perfect Climate Comfort Center™ control for
optimal performance.
® U.S. Registered Trademark
Copyright © 1998 Honeywell Inc. • All Rights Reserved
HE220A,B and HE260A,B
Bypass Flow-Through Humidifier

FEATURES/BENEFITS

• Capable of humidifying a large area.
• Proven technology used for high performance
humidification and enhanced comfort.
• Preassembled for quicker installation.
• Small footprint, light weight and reversible
components allow easy mounting on either warm air
supply or return air duct of any forced air furnace.
• Interior components designed for quick maintenance
and service.
• Includes easy-to-use humidity control which mounts
on the wall or duct for more installation flexibility.
• Perfect Climate Comfort Center™ control can be
installed to replace both the thermostat and humidity
control for improved aesthetics and convenience.
• Continuous flushing reduces the frequency of
maintenance in a hard water installation.
Application .......................................................................... 1
Features/Benefits ................................................................ 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 3
Wiring the Humidifier ........................................................... 4
Plumbing the Saddle Valve ................................................. 5
Checking the installation ..................................................... 5
Operating the Humidifier ..................................................... 5
Operation ............................................................................ 6
Maintenance ....................................................................... 6
Checkout Procedure ........................................................... 7
Troubleshooting .................................................................. 7
Replacement Parts ............................................................. 8
PRODUCT DATA
Contents
68-0191-3

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HE220A,B

  • Page 1: Table Of Contents

    Checking the installation ............. 5 Operating the Humidifier ............. 5 Operation ................6 Maintenance ............... 6 Checkout Procedure ............7 Troubleshooting ..............7 Replacement Parts ............. 8 ® U.S. Registered Trademark 68-0191-3 Copyright © 1998 Honeywell Inc. • All Rights Reserved...
  • Page 2: Specifications

    Honeywell Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitée, 155 Gordon Baker Road, North York, Ontario M2H 3N7. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3: Installation

    DIAMETER HumidiCalc+™ Humidifier Sizing Software (software calculates required humidifier capacity for application). M12245 PC8900 Perfect Climate Comfort Center™ Control. Fig. 1. Dimensions of HE220A,B in in. (mm). S688 Sail Switch. INSTALLATION ( 2 3 9 - 1 ( 3 0 WARNING Hazardous Voltage.
  • Page 4: Wiring The Humidifier

    HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER 11. Reinstall the humidifier pad assembly in the humidifier housing. NOTE: Be sure the water feed tube is not pinched or kinked. R I Z 12. Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover.
  • Page 5: Plumbing The Saddle Valve

    HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER PLUMBING THE SADDLE VALVE OPERATING THE HUMIDIFIER Hot or cold water, either hard or softened, can be used in the The HE220A and HE260A humidifier. Humidifiers are controlled by the Convertible Humidity 1. Use the self-piercing saddle valve (included) to tap into Control that is installed either the water supply line at an appropriate location.
  • Page 6: Operation

    OPERATION Every 1 to 3 Months (Depending on Water Quality) The HE220A,B and HE260A,B Humidifiers use the principle Use the following procedure to clean the humidifier: that vapor (evaporated water) is created when warm air blows 1. Disconnect the power and turn off the humidifier water over a water soaked area.
  • Page 7: Checkout Procedure

    HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER 9. Disconnect the tube from the drain fitting on the bottom Vacation of the humidifier housing. When leaving on vacation, turn off the humidifier water supply 10. Clean the drain fitting, if necessary. and the humidity control. When returning from vacation, turn 11.
  • Page 8: Replacement Parts

    HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER REPLACEMENT PARTS Refer to Fig. 6 and Table 8 when ordering replacement parts. M12303A Fig. 6. Exploded view of humidifier parts. 68-0191—3...
  • Page 9 HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER Table 8. List Of Replacement Parts For HE220A,B, HE260A,B Humidifiers. Exploded View Number Description HE220 Part Number HE260 Part Number Side wall 32001612-001 32001626-001 32001612-001 32001626-001 Bypass side wall 32001613-001 32001627-001 32001627-001 32001613-001 Cover Assembly...
  • Page 10 HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER 68-0191—3...
  • Page 11 HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER 68-0191—3...
  • Page 12 HE220A,B AND HE260A,B BYPASS FLOW-THROUGH HUMIDIFIER Home and Building Control Home and Building Control Honeywell Asia Pacific Inc. Honeywell Inc. Honeywell Limited-Honeywell Limitée Room 3213-3225 Honeywell Plaza 155 Gordon Baker Road Sun Hung Kai Centre P.O. Box 524 North York, Ontario No.

This manual is also suitable for:

He260a,bHe220bHe260aHe260b

Table of Contents